SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER 828 By SHERWOOD INDUSTRIES LTD.
8. VENTING WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRA
constructed out of non-combustible materials. Make sure that all chimney clean outs are tightly fitting and will not permit air to leak into the chim
For best venting performance, we recommend total vent height of 10ft (3m) to 30ft (9m). Total horizontal length depends on the number of elbows used.
10. INSTALLATION OF LOG SET and EMBERS A. INSTALLING THE GLOWING EMBERS A bag of ceramic fiber embers is provided for use on the front burner tray.
11. OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY R
12. ROUTINE MAINTENANCEPeriodically check to ensure that the "B-Vent" venting system is clear and that a negative draft is present when the
13. TROUBLE SHOOTING Problem Possible Cause Solution Spark will not arc to the pilot after repeated pressing of spark ignitor Defective piezo igni
14. PARTS AND ACCESSORIES Service Parts available from your local ENVIROGAS Dealer. PART # DESCRIPTION 828-001 Convection Blower 828-002 Heyco Str
1815. WARRANTY Sherwood Industries Ltd. offers a *Lifetime Warranty on this gas product. The lifetime warranty covers the appliance for a period of
16. INSTALLATION DATA SHEET The following information must be recorded by the installer for warranty purposes and future reference. Envirogas Model
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" ROOM HEATER, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION:
TABLE OF CONTENTS 1 Code Approvals...
FOR INSTALLATIONS ABOVE 2000 FEET • In Canada, these appliances are certified for altitudes of 0-2,000 feet and must be derated by 10% for installat
4. DECIDING WHERE TO LOCATE YOUR FREESTANDING STOVE 1. The stove should be located out of traffic and away from furniture and draperies. 2. This sto
* As specified in CGA B149 Installation Codes (1991) Note: Local Codes or Regulations may require different clearances. 5. ASSEMBLY AND INSTALLATION
13. Re-attach the hinged side flaps by sandwiching the surround panels between the mounting brackets and the hinged side flaps. secure with screws.
6. ELECTRICAL REQUIREMENTS The ENVIROGAS 828 Series will operate without an external electrical power supply. This model has a Millivolt gas contr
7. GAS LINE CONNECTION AND TESTING WARNING: Only persons licensed to work with gas piping can make the gas connections to this appliance. This applia