SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Kodiak
Wood Stove
Models: 1200 & 1700 Insert and 1200 & 1700 Fireplace Freestanding
Tested &
Listed By
Beaverton
Oregon USA
OMNI-Test Laboratories, Inc,
C
O-
T L
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD
BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT
IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
Contact your local building or re ofcials, or the authority having jurisdiction
about restrictions and installation inspection requirements in your area.
This heater meets the U. S. Environmental Protection Agencies
emission limits for wood heaters sold after July 1st, 1990.
Under specic conditions this heater has been shown to deliver
heat at rates ranging from 11,479 to 34,196 BTU per hour for
the 1200 and from 9,425 to 31,780 BTU per hour for the 1700.
50-1040
Zobrazit stránku 0
1 2 3 4 5 6 ... 49 50

Shrnutí obsahu

Strany 1 - OWNER’S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Strany 2 - Table of Contents

Operating InstructionsHOW IT WORKS:1/2" Ceramic baffle;reflects heat downto burn up smoke.Secondary air tubes;creates a secondaryburn on the part

Strany 3 - Safety Precautions

11Specifications1200 SPECIFICATIONS:Model 1200 Freestanding 1200 InsertFlat Top Step TopWidth x Depth 25” x 22 7/16” (635 mm x 570 mm)27” x 21” (70

Strany 4

Specifications1700 SPECIFICATIONS:Model 1700 Freestanding 1700 InsertFlat Top Step TopWidth x Depth 25” x 26 15/16” (635 mm x 684 mm)27” x 26” (705

Strany 5

13SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 INSERT:A Minimum clearance to an unshielded side wall10” (254 mm)B Minimum clearance to an unshielde

Strany 6

SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Single Wall Pipe Double Wall

Strany 7

15SpecificationsCLEARANCES TO COMBUSTIBLES - 1700 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Single Wall Pipe Double Wa

Strany 8

SpecificationsDIMENSIONS - 1200 INSERT:3/16"(5mm)183/8"(467mm)Regular Surround2715/16" (709mm)OversizedSurround333/16"(709mm)191/8

Strany 9

17SpecificationsDIMENSIONS - 1200 INSERT:337/8" (860mm)461/8" (1171mm)273/4" (705mm)3/16"(5mm)183/8"(467mm)Regular Surround27

Strany 10 - Operating Instructions

SpecificationsDIMENSIONS - 1200 FREESTANDING:25"(635mm)61/16"(153mm)915/16"(252mm)281/4"(718mm)2915/16"(760mm)301/4"(769

Strany 11 - Specifications

19SpecificationsDIMENSIONS - 1700 FREESTANDING:2615/16"(684mm)915/16"(252mm)157/8"(403mm)25"(635mm)193/8"(492mm)61/16"(1

Strany 12

Table of Contents2Safety Precautions...3Operating Instructi

Strany 13

SpecificationsFREESTANDING SIDE DIMENSIONS FOR FAN KIT:    

Strany 14

21InstallationPlease read and understand these instructions before installing pedestal or ash pan and leg option. Failure to follow thes

Strany 15

• Place the unit on the pallet on its back.• Attach pedestal spacer to bottom of the unit, using the supplied screws.• Attach the air channel box

Strany 16

23InstallationOUTSIDE AIR KIT:It is mandatory to use outside air for installations in mobile homes.A 4” (10.2 cm) fresh air adaptor kit is av

Strany 17

InstallationCHIMNEY INSTALLATION THROUGH WALL:Here are four (4) methods of combustible wall chimney connector pass-throughs. Information was provided

Strany 18

25InstallationINSTALLATION OF A LISTED, FACTORY BUILT CHIMNEY - FREESTANDING:This is a generic set of instructions; always follow the chimney manufact

Strany 19

InstallationHearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorChimneyconnectorCeilingInsulated chimneyRoof flashing

Strany 20

27InstallationMASONRY CHIMNEY INSTALLATION - FREESTANDING:DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.A non-combustible oo

Strany 21 - Installation

Figure 29: Freestanding Installation into existing replace.Unless you are experienced, we recommend installation by your dealer or a professional ins

Strany 22

29At least3 feet (914 mm)HearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorDouble wall pipeCeiling supportCeilingSp

Strany 23

3Safety PrecautionsFOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:● Please read this

Strany 24

InstallationMASONRY FIREPLACE INSTALLATION - INSERT:Unless you are experienced, we recommend installation by your dealer or a professional installer.I

Strany 25

The ue collar is removable for installations into replaces with low openings. a) Remove the rst two (2) front secondary air tube

Strany 26

32InstallationFigure 35: Attaching removable ue.Figure 36: Leveling leg.SURROUND PANEL SEALED INSTALLATION FOR USA ONLY - INSERT:Before starting th

Strany 27

33InstallationINSTALLATION USING A BLOCK-OFF PLATE FOR USA ONLY - INSERT:If this unit is to be installed into a masonry replace or a zero-clearance 

Strany 28

34Installation5. Mount the block-off plate using masonry screws in a masonry replace and sheet metal screws on a zero-clearance repl

Strany 29

InstallationMODEL 1200 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacing

Strany 30

InstallationMODEL 1700 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacing

Strany 31

37InstallationDOOR INSTALLATION:Please inspect all components for damage. If damage has occurred, please contact the courier company, dealer, or distr

Strany 32

CERAMIC BAFFLE INSTALLATION:1. Remove the front secondary air tube by placing a screwdriver (any style except at head) into one of Left CeramicBaffle

Strany 33

39The fan kit is pre-installed into the left shroud that comes with your unit. If a decorative set of shroud plates is purchased, the fan as

Strany 34

Operating InstructionsFIRST STARTWhen rst installed, the chimney, rebricks and steel are cold and it usually takes several hours on a fairly high bu

Strany 35

Figure 52: Changing decorative plate.InstallationREMOVAL OF THE SHROUDS - INSERT:ABB1. If the surround panel is installed, remove it by lifting the p

Strany 36

41InstallationINSTALLATION OF THE SURROUND PANEL - INSERT:Figure 55: Screw to hold the trim against the sur-round.Figure 53: Corner brackets for trim.

Strany 37

Parts ListReferance NumberDescription Part Number1 120°F (49°C) Ceramic Fan Temperature Sensor EC-0012 Domestic power cord - 115V EC-042Convection Blo

Strany 38

43Parts ListReferance NumberDescription Part Number26 Door Handle Assembly (Rod, Cast Latch, Brass Spring) 50-112127 Wood Door Glass Retainer Kit (Wit

Strany 39

Parts Diagram - Freestanding3130343529283332151719184625444277926142161721202322244345816Kodiak - Freestanding ComponentsOctober 200444

Strany 40 - Figure 52: Changing

45Parts Diagram - Pedestals & Legs111310124139405383637Kodiak - Pedestal and Leg Kit ComponentsMay 2006

Strany 41 - Figure 55: Screw to hold

Parts Diagram - Fireplace Insert4915535447850485152544223Kodiak - Fireplace Insert ComponentsOctober 2004Common parts are shown inParts Diagram - Free

Strany 42 - Parts List

47WarrantySherwood Industries Ltd. Limited Lifetime WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sh

Strany 43

Warranty6. If the problem is not covered by the Limited Warranty, the customer will be responsible for all repair costs, as well as all storage, shi

Strany 44 - Parts Diagram - Freestanding

49d) Salt air in coastal areas or high-humidity can be corrosive to the nish; these environments can cause rusting. Damage caused by

Strany 45 - May 2006

REPLACING THE GLASS:Never strike or slam the door, hit the glass or let burning wood rest against it. If the glass cracks when the re is burning, do

Strany 46 - Common parts are shown in

50Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Strany 47 - Warranty

6Operating InstructionsMAINTENANCE:At the end of each heating season clean the chimney and the smoke pipe. If soot has accumulated above the top bafe

Strany 48

7Operating Instructionsc) DO NOT OVERFIRE. If the heater or chimney connector glows, you are overring.d) CAUTION: DO NOT PLACE FUEL WITHIN SPACE HEAT

Strany 49

8Operating Instructionslength for the logs used in the 1200 would be about 16“ (381 mm) but it can burn pieces up to 18” long. Ideal length for the lo

Strany 50 - Installation Data Sheet

9Operating Instructionsa) Air supply – Inside the home, normal household appliances such as clothes dryers and forced-air furnaces compe