Enviro Kodiak 1200 Insert Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Nástroje Enviro Kodiak 1200 Insert. Enviro Kodiak 1200 Insert User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 55
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED
PAPER.
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNERS MANUAL
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Kodiak
Wood Stove
Models: 1200 & 1700 Insert and 1200 & 1700 Fireplace Freestanding
Tested &
Listed By
Beaverton
Oregon USA
OMNI-Test Laboratories, Inc,
C
O-
T L
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD
BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT
IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.
Contact your local building or re ofcials, or the authority having jurisdiction
about restrictions and installation inspection requirements in your area.
This heater meets the U. S. Environmental Protection Agencies
emission limits for wood heaters sold after July 1st, 1990.
Under specic conditions this heater has been shown to deliver
heat at rates ranging from 11,479 to 34,196 BTU per hour for
the 1200 and from 9,425 to 31,780 BTU per hour for the 1700.
50-1040
INSTALLER: Leave this manual with the wood stove.
CONSUMER: Retain this manual for future reference.
Zobrazit stránku 0
1 2 3 4 5 6 ... 54 55

Shrnutí obsahu

Strany 1 - OWNER’S MANUAL

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.B Y : S H E R W O O D I N D U S T R I E S

Strany 2 - Table of Contents

Operating InstructionsHOW IT WORKS:1/2" Ceramic baffle;reflects heat downto burn up smoke.Secondary air tubes;creates a secondaryburn on the part

Strany 3 - Safety Precautions

11Specifications1200 SPECIFICATIONS:Model 1200 Freestanding 1200 InsertFlat Top Step TopWidth x Depth 25” x 22 7/16” (635 mm x 570 mm)27” x 21” (70

Strany 4

Specifications1700 SPECIFICATIONS:Model 1700 Freestanding 1700 InsertFlat Top Step TopWidth x Depth 25” x 26 15/16” (635 mm x 684 mm)27” x 26” (705

Strany 5

13SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 INSERT:A Minimum clearance to an unshielded side wall10” (254 mm)B Minimum clearance to an unshi

Strany 6

14SpecificationsCLEARANCES TO COMBUSTIBLES - 1700 INSERT:A Minimum clearance to an unshielded side wall10” (254 mm)B Minimum clearance to an unshi

Strany 7

SpecificationsCLEARANCES TO COMBUSTIBLES - 1200 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Table 9: 1200 Freestanding C

Strany 8

SpecificationsCLEARANCES TO COMBUSTIBLES - 1700 FREESTANDING:MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*Table 10: 1700 Freestanding

Strany 9

17SpecificationsDIMENSIONS - 1200 INSERT:3/16"(5mm)183/8"(467mm)Regular Surround2715/16" (709mm)OversizedSurround333/16"(709mm)191

Strany 10 - Operating Instructions

SpecificationsDIMENSIONS - 1200 INSERT:337/8" (860mm)461/8" (1171mm)273/4" (705mm)3/16"(5mm)183/8"(467mm)Regular Surround2715

Strany 11 - Specifications

19SpecificationsDIMENSIONS - 1200 FREESTANDING:25"(635mm)61/16"(153mm)915/16"(252mm)281/4"(718mm)2915/16"(760mm)301/4"(7

Strany 12

Table of Contents2Safety Precautions...3Operating Instructi

Strany 13

SpecificationsDIMENSIONS - 1700 FREESTANDING:2615/16"(684mm)915/16"(252mm)157/8"(403mm)25"(635mm)193/8"(492mm)61/16"(153

Strany 14

21SpecificationsFREESTANDING SIDE DIMENSIONS FOR FAN KIT:   

Strany 15

InstallationPlease read and understand these instructions before installing pedestal or ash pan and leg option. Failure to follow these

Strany 16

23• Place the unit on the pallet on its back.• Attach pedestal spacer to bottom of the unit, using the supplied screws.• Attach the air channel b

Strany 17 - /8" (683mm)

InstallationHEARTH PROTECTION EXAMPLES:Table 11: Examples of Hearth Pad Sizing Using Clearances From Tables 9 &10 (refer to Figures 19 & 20).C

Strany 18

Installation25Door OpeningIAGCUSA 16" (406mm)CND 18" (457mm)EUSA 6"(152mm)CND 8"(203mm)USA 6" (152mm)CND 8" (203mm)H DFB

Strany 19

26Table 13: Examples of Corner Installation Using Clearances From Tables 9 &10 (refer to Figures 20 & 21).(K) Front of Hearth Pad to Corner (

Strany 20

InstallationOUTSIDE AIR KIT:It is mandatory to use outside air for installations in mobile homes.A 4” (10.2 cm) fresh air adaptor kit is avai

Strany 21

InstallationCHIMNEY INSTALLATION THROUGH WALL:Here are four (4) methods of combustible wall chimney connector pass-throughs. Information was provided

Strany 22 - Installation

29InstallationINSTALLATION OF A LISTED, FACTORY BUILT CHIMNEY - FREESTANDING:This is a generic set of instructions; always follow the chimney manufact

Strany 23

3Safety PrecautionsFOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” WOOD STOVE, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:● Please read this

Strany 24

InstallationHearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorChimneyconnectorCeilingInsulated chimneyRoof flashing

Strany 25

31InstallationMASONRY CHIMNEY INSTALLATION - FREESTANDING:DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.A non-combustible oo

Strany 26

Figure 32: Freestanding Installation into existing replace.Unless you are experienced, we recommend installation by your dealer or a professional ins

Strany 27

33At least3 feet (914 mm)HearthpadFloorPedestalWoodstoveOptionalfanOutside air connectionthrough wall or floorDouble wall pipeCeiling supportCeilingSp

Strany 28

InstallationMASONRY FIREPLACE INSTALLATION - INSERT:Unless you are experienced, we recommend installation by your dealer or a professional installer.I

Strany 29

35The ue collar is removable for installations into replaces with low openings. a) Remove the rst two (2) front secondary air tube

Strany 30

InstallationFigure 38: Attaching removable ue.Figure 39: Leveling leg.SURROUND PANEL SEALED INSTALLATION FOR USA ONLY - INSERT:Before starting this

Strany 31

37InstallationINSTALLATION USING A BLOCK-OFF PLATE FOR USA ONLY - INSERT:If this unit is to be installed into a masonry replace or a zero-clearance 

Strany 32

Installation5. Mount the block-off plate using masonry screws in a masonry replace and sheet metal screws on a zero-clearance replac

Strany 33

39InstallationMODEL 1200 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacin

Strany 34

Operating InstructionsFIRST STARTWhen rst installed, the chimney, rebricks and steel are cold and it usually takes several hours on a fairly high bu

Strany 35

InstallationMODEL 1700 BRICK PLACEMENT & TUBE LOCATIONS:COMPLETE THE STOVE AND SMOKE PIPE INSTALLATION BEFORE PLACING THESE BRICKS.When replacing

Strany 36

41InstallationDOOR INSTALLATION:Please inspect all components for damage. If damage has occurred, please contact the courier company, dealer, or distr

Strany 37

CERAMIC BAFFLE INSTALLATION:1. Remove the front secondary air tube by placing a screwdriver (any style except at head) into one of Left CeramicBaffle

Strany 38

43The fan kit is pre-installed into the left shroud that comes with your unit. If a decorative set of shroud plates is purchased, the fan as

Strany 39

Figure 55: Changing decorative plate.InstallationREMOVAL OF THE SHROUDS - INSERT:ABB1. If the surround panel is installed, remove it by lifting the p

Strany 40

45InstallationINSTALLATION OF THE SURROUND PANEL - INSERT:Figure 58: Screw to hold the trim against the sur-round.Figure 56: Corner brackets for trim.

Strany 41

Parts ListReferance # Description Part #1 120°F (49°C) Ceramic Fan Temperature Sensor EC-0012 FPI Fan Controller - 115V EC-0392 Fan Controller Knob EC

Strany 42

47Parts ListReferance # Description Part #24 Pumice Bricks - 4” X 4” (114mm x 114mm) 50-110625 1200 & 1700 Ash Dump Cover 50-112026 Door Handle

Strany 43

Parts Diagram - Freestanding3130343529283332151719184625444277926143161721202322244345816Kodiak - Freestanding ComponentsApril 200748

Strany 44 - Figure 55: Changing

49Parts Diagram - Pedestals & Legs111310124139405383637Kodiak - Pedestal and Leg Kit ComponentsMay 2006

Strany 45 - Figure 58: Screw to hold

REPLACING THE GLASS:Never strike or slam the door, hit the glass or let burning wood rest against it. If the glass cracks when the re is burning, do

Strany 46 - Parts List

Parts Diagram - Fireplace Insert4915535447850485152544232Kodiak - Fireplace Insert ComponentsApril 2007Common parts are shown inParts Diagram - Freest

Strany 47

51WarrantySherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to

Strany 48 - Parts Diagram - Freestanding

Warranty5. If Sherwood Industries Ltd. determines that the stove needs to be returned to Sherwood Industries Ltd. for repair, the customer has the res

Strany 49 - May 2006

53Warranty11. The Limited Warranty does not cover installation and operational related problems such as use of downdrafts or spillage caused by envir

Strany 50 - Common parts are shown in

Warranty24. Sherwood Industries Ltd. will not cover the cost of the removal or re-installation of the stove, hearth, facing, mantels, venting or othe

Strany 51 - Warranty

55Installation Data SheetThe following information must be recorded by the installer for warranty purposes and future reference.NAME OF OWNER:________

Strany 52

6Operating InstructionsMAINTENANCE:At the end of each heating season clean the chimney and the smoke pipe. If soot has accumulated above the top bafe

Strany 53

7Operating Instructionsc) DO NOT OVERFIRE. If the heater or chimney connector glows, you are overring.d) CAUTION: DO NOT PLACE FUEL WITHIN SPACE HEAT

Strany 54

8Operating Instructionslength for the logs used in the 1200 would be about 16“ (381 mm) but it can burn pieces up to 18” long. Ideal length for the lo

Strany 55 - Installation Data Sheet

9Operating Instructionsa) Air supply – Inside the home, normal household appliances such as clothes dryers and forced-air furnaces compe

Komentáře k této Příručce

Žádné komentáře